Laparoscopy Intestinal Grasper: 10mm Advanced Bowel Handling( Premium Series )
Product Details
Intestinal Grasper: 10mm Advanced Bowel Handling
Key Features of the Intestinal Grasper
1. Extra-wide 10mm jaws
The Intestinal Grasper features extra-wide 10mm jaws designed to provide a broader tissue-contact area during grasping. This configuration is intended to distribute the gripping force across a larger surface rather than concentrating it at a narrow contact point.
Jaw dimensions are an important consideration when selecting a grasper for bowel manipulation. The appropriate instrument depends on the tissue, intended task and manufacturer's specifications.
2. Fenestrated jaw design
The fenestrated jaws feature an open-window configuration that distinguishes this instrument from solid-jaw graspers. Fenestration changes the jaw's contact pattern and provides a defined gripping structure for suitable tissue-handling tasks.
The overall effect on tissue pressure depends on the jaw geometry, applied force and tissue characteristics. Fenestration alone does not guarantee prevention of bowel injury.
3. Smooth inner jaw surfaces
The smooth inner jaw surfaces are designed to support controlled tissue contact during manipulation. This feature is relevant when evaluating instruments intended for bowel handling, where the contact surface is an important design consideration.
Actual tissue interaction depends on instrument condition and technique. Avoid interpreting the smooth surface as a guarantee against serosal damage.
4. 45° angled shaft
The 45° angled shaft provides an angled approach to the target area. This geometry can be a useful consideration when assessing instrument positioning and access within a laparoscopic surgical setup.
The suitability of the angle depends on the operative approach, anatomy and available working space.
5. Design for laparoscopic bowel handling
The Intestinal Grasper is intended for colorectal and bariatric procedures. Its wide fenestrated jaws, smooth inner surfaces and angled shaft provide specific design characteristics for surgical teams to evaluate when selecting an instrument for bowel manipulation.
6. Reusable configuration
The instrument is specified as reusable. Cleaning, inspection, maintenance and sterilization must follow the manufacturer's validated instructions for use. The jaw openings and moving mechanism should be inspected as directed by the manufacturer.
Intestinal Grasper for Controlled Bowel Handling
The Intestinal Grasper is designed for bowel manipulation in laparoscopic procedures where jaw configuration and instrument positioning are important selection factors. Its 10mm-wide jaws provide a broader contact profile, while the fenestrated structure and smooth inner surfaces define how the instrument engages tissue.
The angled shaft provides an additional positioning characteristic for suitable surgical approaches. These features help distinguish the instrument from other laparoscopic graspers, but they do not establish a guaranteed reduction in tissue injury. Appropriate selection and handling depend on the intended task, tissue characteristics and the manufacturer's instructions.
Applications in Colorectal and Bariatric Procedures
Colorectal procedures
In colorectal surgery, instruments may be needed to manipulate bowel tissue during appropriate laparoscopic tasks. The Intestinal Grasper's wide fenestrated jaws and angled shaft are relevant characteristics to consider when evaluating an instrument for this purpose.
Bariatric procedures
The instrument is also specified for bariatric procedures. Its jaw width, inner-surface design and shaft angle provide practical comparison points when selecting a laparoscopic grasper for the intended procedure.
For either application, verify the instrument's approved intended use and complete technical details before clinical use.
Intestinal Grasper Specifications
| Specification | Details |
|---|---|
| Product name | Intestinal Grasper |
| Jaw width | 10mm |
| Jaw design | Wide, fenestrated |
| Inner jaw surface | Smooth |
| Shaft angle | 45° |
| Tip length | Confirm before publishing — supplied as “22m” |
| Reusable | Yes |
| Ideal applications | Colorectal and bariatric procedures |
Why Consider the VOGEL Intestinal Grasper?
When evaluating a laparoscopic bowel grasper, surgical teams should consider jaw width, fenestration, inner-surface design, shaft angle and overall instrument dimensions. The Intestinal Grasper combines a specified 10mm jaw width with fenestrated jaws, smooth inner surfaces and a 45° angled shaft.
These details help hospitals, surgical centres and procurement teams compare instrument configurations against their requirements. Before purchase or use, confirm the tip-length unit, full instrument dimensions, intended use and validated reprocessing instructions.
Explore the VOGEL laparoscopy instrument range for related instruments used in minimally invasive surgery. You can also review the VOGEL Laparoscopy Intestinal Grasper product page if it corresponds to this exact product. Avoid creating a duplicate product page if this is the same instrument.
Vogel By D.R.Surgicare+1
For product information and purchasing enquiries, visit the VOGEL contact page.
Vogel By D.R.Surgicare
Frequently Asked Questions
What is an Intestinal Grasper used for?
According to the supplied details, the Intestinal Grasper is intended for bowel handling in colorectal and bariatric procedures, subject to its approved intended use.
What is the jaw width of this Intestinal Grasper?
The supplied specifications list a jaw width of 10mm.
What is the benefit of fenestrated jaws?
Fenestrated jaws have an open-window design that defines the tissue-contact pattern. The suitability of this configuration depends on the intended grasping task and instrument design.
Does the Intestinal Grasper have an angled shaft?
Yes. The supplied specifications list a 45° angled shaft.
What is the tip length?
The supplied value is “22m,” which appears incomplete or incorrectly formatted. Confirm the correct measurement and unit before publishing.
Is the Intestinal Grasper reusable?
Yes. It is specified as reusable. Follow the manufacturer's validated instructions for cleaning, inspection, maintenance and sterilization.
Package contents for Laparoscopy Intestinal Grasper: 10mm Advanced Bowel Handling( Premium Series ) have not been specified. Please confirm the supplied items and accessories before ordering.
For shipping, returns and applicable conditions, please read our Returns & Refunds Policy.
Are these instruments autoclavable?
Yes. Every VOGEL instrument is fully autoclavable and built for repeated sterilization cycles.
Do you supply in bulk to hospitals and distributors?
Yes. Institutional and distributor pricing is available — contact our sales team with your requirement list.
Is a GST invoice provided?
A GST-compliant invoice is issued with every order.